Founded in 1970, Viracon is a leading single-source architectural glass fabricator. We partner with best-in-class architecture firms and glazing contractors to provide great buildings with great glass - glass that inspires and turns buildings into icons. Viracon glass has been installed in over 100,000 buildings with more than half a billion square feet of glass delivered on time and exceeding expectations around the globe.
Viracon manufactures and fabricates production at headquarters in Owatonna, Minnesota
PRODUCTS
INSULATED GLASS (IGU)
Viracon insulating glass consists of two or more plies of glass enclosed with a hermetically sealed spacer. Triple insulating glass units are constructed with three plies of glass separated by two hermetically sealed spacers.
Insulating glass is designed to enhance solar and thermal performance using Low-E coatings protected by hermetically sealed spaces filled with Argon. The design provides a barrier to water and moisture infiltration and reduces condensation. Triple insulating glass further reduces the U-Value by offering the opportunity to place Low-E coatings on both the #2 and #4 surfaces.
HIGH-PERFORMANCE COATINGS
40 years ago, Viracon started coating glass and today we influence the options, quality, performance and breadth of coatings for architectural glass in North America and beyond.
Low-E coatings are thin layers of metal applied to glass to improve solar performance. The specific coating needed for a given project is typically dictated by a required solar performance or desired appearance.
RoomSide® Low-E
Viracon RoomSide® Low-E is applied to the interior-facing surface of an insulating glass unit to reflect radiant heat back into the building and improve thermal performance. When combined with a high-performance coating, argon fill, and a VTS® warm-edge spacer, it can improve the U-value of dual-pane insulating glass by up to 20%, providing performance comparable to some triple-pane configurations without the added weight, thickness, and glazing-system complexity. This makes RoomSide® Low-E a valuable option for projects in Utah’s colder climate zones where improved winter performance is a priority.
HEAT TREATMENT
Heat treating glass—through a controlled tempering process—significantly improves its durability and performance. Compared to annealed glass, heat-treated glass offers greater resistance to thermal and mechanical stresses and is engineered to break in specific patterns that enhance safety in glazing applications. This transformation occurs as the glass passes through a tempering furnace, altering its physical characteristics to meet demanding structural and environmental requirements. At Viracon, heat treatment is performed prior to applying Low-E coatings in accordance with ASTM C1048 standards for heat-strengthened and fully-tempered flat glass.
PGP West represents Viracon Glass in Utah, Idaho, and Montana. Our team supports architects, contractors, developers, and building owners with product selection, specifications, details, samples, budgeting, and project coordination.
Connect with PGP West to explore Viracon glass options for your next project. Our team can assist with coatings, glass configurations, samples, specifications, and performance data. We help align each selection with your architectural vision, Utah’s climate conditions, and the project’s energy and building-envelope performance requirements.
Design with VIRACON
Why Viracon?
Viracon combines extensive glass fabrication capabilities with in-house coating development, experienced technical support, and more than one million possible product configurations. Its distinctive cut-temper-coat process applies high-performance coatings after heat treatment, helping improve glass flatness, optical quality, and color consistency across the façade. With insulating, laminated, and monolithic glass options, along with custom coatings, printing, bird-friendly solutions, spandrel, and specialty fabrication, Viracon gives architects the flexibility to balance appearance, daylight, solar control, thermal performance, acoustics, safety, and security within a single coordinated glass solution.
design & education
-
Viracon insulating glass with a high-performance low-e coating can help reduce heat loss, improve interior comfort, and limit condensation during colder conditions. The appropriate configuration depends on the project’s climate zone, window-to-wall ratio, framing system, orientation, and energy-performance requirements. RoomSide® Low-E, argon fill, laminated glass, and warm-edge spacers may provide additional performance benefits. Connect with your local PGP West team member to discuss Viracon glass coatings for your next project.
-
Viracon RoomSide® Low-E is applied to the interior-facing surface of an insulating glass unit and reflects radiant heat back into the building. When combined with a high-performance coating, argon fill, and a VTS® warm-edge spacer, it can improve the U-value of dual-pane insulating glass by up to 20%. This can provide performance comparable to some triple-pane configurations without the additional weight, thickness, and glazing-system complexity.
-
Low-e coatings should be selected by evaluating visible light transmittance, solar heat gain coefficient, U-value, exterior reflectance, color, and the building’s orientation. Viracon offers coatings across a broad range of performance and appearance options, allowing architects to balance daylight, solar control, thermal performance, and façade design.
-
Montana adopted the 2024 International Energy Conservation Code with state amendments effective September 26, 2026. Required fenestration performance varies by climate zone, building type, glazing percentage, and compliance path. Project teams should evaluate U-value, solar heat gain coefficient, air leakage, safety glazing, structural loads, and the performance of the complete framing and glass assembly.
-
Viracon glass can be configured to support projects designed under Utah’s adopted commercial energy code, including the 2024 IECC and ASHRAE 90.1-2022 with state amendments. Compliance depends on the complete fenestration assembly, project location, glazing area, building type, and selected compliance path. PGP West can help evaluate Viracon coatings and glass configurations against the project’s specified performance criteria.
Viracon offers insulating glass, insulating laminated glass, high-performance Low-E coatings, warm-edge spacers, and RoomSide® Low-E options that can be configured for Utah commercial energy-code requirements. Compliance depends on the project’s climate zone, building type, window-to-wall ratio, orientation, framing system, and energy-code compliance path.
-
Boise requires bird-friendly glazing for qualifying new construction, renovations, additions, high-risk building features, and projects within designated Bird Activity Zones.
Accepted solutions include products with an American Bird Conservancy Threat Factor of 30 or less and other approved treatments. Viracon offers SoarSafe® first-surface laser-etched glass and ceramic-enamel patterns designed to meet established bird-friendly criteria while remaining compatible with high-performance low-e coatings.
-
Utah does not currently have one statewide bird-friendly glazing requirement for every building, but local zoning, environmental conditions, owner standards, and sustainability goals may require or encourage its use. Viracon offers SoarSafe® first-surface laser-etched glass and ceramic-enamel printed patterns designed around recognized 2-by-2 and 2-by-4 spacing guidelines.
-
Utah currently follows the 2024 International Energy Conservation Code for commercial construction, with state amendments and ASHRAE 90.1-2022 available as a compliance path. The applicable requirements should be confirmed with the local authority having jurisdiction when the project is submitted for permit.
-
Yes. Viracon laminated and insulating laminated glass can improve STC and OITC performance for buildings near highways, airports, railways, entertainment districts, and other exterior noise sources. The appropriate glass configuration should be selected according to the project’s acoustic criteria and coordinated with the surrounding framing and wall assembly.
-
Required U-values and solar heat gain coefficients depend on the adopted energy code, climate zone, project type, window-to-wall ratio, and compliance method. The glass, spacer, framing system, and surrounding wall assembly must be evaluated together because center-of-glass values do not represent the performance of the complete fenestration system. Connect with your local PGP West team member to learn more about Viracon glass performance.
-
Utah includes Climate Zones 3B, 5B, and 6B, creating different performance needs across the state. Glass for projects in St. George, Salt Lake City, Park City, and northern Utah should be selected according to the local climate, façade orientation, energy model, daylighting goals, and complete framing assembly.
As a leading single-source architectural glass fabricator, Viracon is committed to helping you realize your vision and accomplish your design goals with our innovative, high-quality, customizable architectural glass products that transform buildings into iconic structures. For over 50 years, Viracon has been a committed partner, supporting your success and helping you build beautiful glass facades on some of the world’s most inspiring projects.